You will want to look your pump over very carefully and get acquainted with the pump prior to starting. Also refer to "Operating Instructions and Maintenance Suggestions" or "Operators Manual" published by WGI for the specific pump type and model.
I. WARNINGS AND PRECAUTIONS BEFORE AND
AFTER
STARTING A WGI RECIPROCATING PUMP.
A. Safety Precautions
1. Never start or operate a pump against a closed discharge line. Catastrophic destruction of piping or pump will promptly occur.
2. Avoid starting against a full discharge load. Bring pump up to speed using a bypass, then gradually place pump on line.
3. Bleed air from pump and piping before starting pump.
4. The cradle cover must be in place while pump is running.
5. Stand clear of pump while operating under pressure.
6. Do not operate pump above "maximum design pressure" indicated on metal tag. Operating above the maximum design pressure will result in damage to pump, person or property. Notify WGI at the first sign of a suspected malfunction.
7. Contact WGI immediately if operating conditions or type of service change. Upon request you can receive recommendations to meet the new specifications and a new application tag can be sent.